Between Rails Generator Set: MODEL BRG-112 

Klinge's BRG-540PL Between Rails Generator Set is a self contained automatic generator set designed to operate independently. The generator set can be mounted to either 20-foot or 40-foot ISO chassis that have 203, 254 or 305 mm (8, 10 or 12 inch) main rails. It attaches to the lower rail of the chassis beam between chassis cross members. The cross members should provide approximately 914 mm (36 inches) of free space between them so that the unit may be properly mounted.

BRG-112 PHOTOS

BRG-112 SPECIFICATION

» Dimensions: L 1219 mm (48 in) / 1397 mm (55 in) with mounts, W 1330 mm (52.37 in) / 1578 mm (62.12 in) with mounts. The width of the frame that goes between the chassis rails is 699 mm (27.5 in), H 762 mm (30 in)
» Weight: 408 kg (900 lb) without fuel / 578 kg (1275 lb) with fuel
» Construction: Frame is made out of steel, doors and panels are made out of aluminum
» Engine: Yanmar Diesel 3TNV70-HGE, 4 stroke, 3 cylinder, liquid cooled, vertical in line, 47.8 cu. in. (0.784 liter), 18.4 bhp ( 13.7 kW) @ 3600 rpm continuous, 20.2 bhp ( 15.1 kW) @ 3600 rpm intermittent, cooling fan: pusher type, 5 blades, battery charging alternator 14V / 40 amp
» Power Alternator: 12 kW / 15 kVA, cos fi 0.8, 480 / 227 V 60 Hz ( 3600 rpm), 18 / 31.3 A, 54 kVA max. pickup capacity, two poles, with brushes, single bearing, IP23 protection, compound regulated on 3 phases, class H insulation
» Power Receptacle: CEE 17 / 32 A
» Fuel Tank Capacity: 190 liters (50 US gallons); ensures approximately 65 hours of operation under load
» Controls: Two switches, "ON-OFF" and "START-PREHEAT", AC Voltmeter "0-600 V" for power generating control, Amp Meter "-50 - 0 - +50 A" for the DC circuit control, Engine Hour Meter, Oil Pressure and Temperature Gauge, Engine Fault Protection Unit with shut down functions for High Temperature and Low Oil Pressure with red LED indicators for cause of shut down, Green LED indicator for "Unit in Function"