Nose Mount Generator Set: MODEL NMG-115
Klinge's NMG-115 is a self-powered, integral generator set for use with Nose Mount Refrigeration Unit Model NMR-262. The integral generator set powers the NMR-262 Refrigeration Unit during transit or whenever shore power is not available. The NMG-115 Generator Set and NMR-262 Refrigeration Unit were designed for 20' and 40' Insulated ISO Containers.
The NMG-115 & NMR-262 Refrigerated Container features dual refrigeration units (primary and back-up) for the transport of hazardous, temperature-sensitive, or highly valuable goods.
Klinge's machinery complies with International Customs Regulations for Containers, relevant ISO recommendations, and the rules of B.V., ABS and Lloyds.
NMG-115 & NMR-262 PHOTOS (Redundant System)


NMG-115 & NMR-262 FEATURES (Redundant System)
» The ideal solution for
hazardous and high-value cargo that requires extra protection.
» Total redundancy—Two complete and separate refrigeration systems, each
with their own thermostat and control circuit.
» Components in the evaporator section are explosion protected in
accordance with the EX G3 norm (UL Class 1 Group D).
» Two individual Microprocessor Controllers provide reliable temp.
control with an accuracy of ±0.4°F (±0.25°C) in extreme environments.
» Back-up Nose-Mount Generator Set capable of powering the
Refrigeration Unit if loss of external power supply occurs or during
transport on a truck.
» All components (except evaporator coil) are serviceable from front of the unit.
» NMG-115 can be quickly and easily mounted to the container using only
4 bolts.
» Easy access to all components in electric box—door has lift off
hinges.
» Complies with IMDG regulations for the transport of Classes 4.1
through 5.2.
NMG-115 SPECIFICATION
» Dimensions: W
86.0 in (2184 mm), D 23.5 in (597 mm),
H 35.0 in (889 mm)
» Weight: 1680 lbs (762 kg) with full fuel tank,
1315 lbs (596 kg) without fuel
» Ambient Temperature Range: -20°F to +125°F (-20°C to +52°C)
» Battery: 55 A, 14 V DC alternator, one
625 A, 12 V DC maintenance-free battery
» Engine: Deutz F3L1011E Oil cooled diesel; three-cylinder,
2.05 I direct injected, 28 BHP, @ 1800 rpm;
250 hr maintenance intervals.
» Fuel System: Fuel strainer; dual fuel filters;
in-line fuel heater; self-priming pump; Diesel Fuel #2, or #1 in cold
temperatures.
» Tank Capacity: 50 gallons (190 I); approximately 56 hours of operation
» Voltage: 460 V AC/3 phase/60 Hz; power circuit
breaker; power receptacle provided
» Controls: Engine fuel solenoid switch; Low oil pressure switch; High
oil temperature switch; Engine hour meter; Engine start/stop toggle switch; Safety shut down system
» OPTIONS: Integral spare parts box, shelving,
datalogger, and
satellite communication system.