Nose Mount Refrigeration Unit: MODEL NMR-171A
Klinge's Nose Mount Refrigeration Unit Model NMR-171A was specifically designed for 20' Insulated ISO Containers. The NMR-171A offers multi-temperature refrigeration with separate freezer and fridge sections.
The NMR-171A is used with their Nose Mount Model Generator Set Model NMG-112. The integral generator set powers the NMR-171A Refrigeration Unit during transit or whenever shore power is not available.
A military version of the 20' Military Refrigerated Container (NMG-112 and NMR-171A) is available — the equipment is designed and qualified to military standards such as Vibration, Category A1 and B2 Cooling, Category C0 Cold Climate, Driving Rain, Salt/Corrosion, and Power Source/Fuel.
Klinge's machinery complies with International Customs Regulations for Containers, relevant ISO recommendations, and the rules of B.V., ABS and Lloyds.
NMR-171A & NMG-112 PHOTOS (20' System)



NMR-171A & NMG-112 FEATURES (20' System)
» Multi-temperature refrigeration offering separate
freezer and fridge sections.
» Moveable bulkhead can be stowed in either direction.
»NMG-112 Generator Set powers the refrigeration unit during
transit or food distribution in the field.
» Refrigeration unit and Generator Set are separate units
and can operate independently.
» Alarm system with blackout lighting in tactical mode.
» Easy operability—designed for use by cooks & soldiers.
» OPTIONS: Shelving, dual voltage, air curtains, side door,
datalogger,
satellite communication system.
NMR-171A SPECIFICATION
» Dimensions: W 83 in (2099 mm), D 20 in (508 mm), H 30 in (769 mm)
» Weight (no fuel): 882 lb (400 kg)
» Ambient Temperature Range: -22ºF (-30ºC) to +122ºC (+50ºC)
» Battery: Fully Sealed, Non-Spillable, 4 stroke, Lead/Acid, 12 V, 750
CCA,
55 AH, RC 120
» Engine: Diesel, Liquid Cooled, Overhead Valves, 4 Stroke, 3 Cylinder
Net Continuous Power Output: 14.5 kW @ 3600 rpm | 12.1 kW @ 3600 rpm
» Fuel: Diesel Fuel or Kerosene-based Fuels (JP-5, JP-8, NATO F34, and
JET-A)
» Tank Capacity: 38 gallons (144 liters) for approximately 50 hours
operation
» Alternator: 3 phase, 2 pole, Single Bearing, Brushless, IP 23, Power
Output 12 kW @ 480 V / 60 Hz | 10 kW @ 400-415 V / 50 Hz
» Controls: Power Circuit Breaker, ‘On’-’Off’ and ‘Start-Preheat’ toggle
switches, Voltmeter 0-600 VAC, DC Amp-Meter, Hour-Meter, Oil Pressure
and Coolant Temperature Gauges, Automatic Shutdown for High Coolant
Temperature, Low Oil Pressure with Light Indicators.
NMR-171A & NMG-112 DRAWINGS (20' System)