CONTAINERIZED
SYSTEM
NMR-071 and NMG-012 |
|
|
|

|
The 10FT Containerized System
is equipped with an integral generator set and can either
run completely independently or on ships or other external
power grid. The Refrigerated Containerized System is
developed to form a vital part of the food distribution
chain for the military and will provide cold storage for
field kitchens. The 10FT System is capable of acting as
either a refrigerator or freezer.
»
Download the NMR-071 and
NMG-012 Brochure |
|
|
|
|
NMR-071A Refrigeration Unit |
NMG-012 Generator Set |
|
|
|
|
General Information: |
General Information: |
|
The NMR-071 container refrigeration unit was
designed for use in the 10’ x 8’ containers and
the 20’ x 8’6” containers.
A microprocessor controller provides reliable temperature
control with an accuracy of ±1°C in extreme environments.
The unit complies with the standards and regulations of the
major classification societies. |
The NMG-012 Generator Set was specifically designed for use
in the 10’ x 8’ containers. The design is compact yet offers
easy access to all service parts.
Tank Capacity:
75 liter for approximately 26 hours of operation |
|
|
|
Construction:
Aluminum Frame
Stainless Hardware |
Construction:
Aluminum Frame
Aluminum doors and closures
Stainless Steel Hardware |
|
Temperature Range: |
|
|
-40°C
to +50°C |
Temperature Range:
-35°C to +
50°C |
|
Dimensions: |
|
Width: 1448 mm
Depth: 1075 mm
Height: 672 mm |
Dimensions:
Length: 1240 mm
Depth: 521 mm (without
fuel)
Height: 775 mm |
|
Weight: |
|
|
230 kg |
Weight:
Weight: 250 kg |
|
|
|
Coils:
Copper tubes, Aluminum Fins,
both corrosion treated |
Engine:
Yanmar, three cylinder, 4 stroke, liquid cooled
16.1 kW @ 3600 rpm / 13.1 kW @ 3000 |
|
Compressor: |
|
Copland scroll,
Hermetic
Defrost:
Hot Gas
Refrigerant:
R-404a
|
Alternator:
Three phases, 2 pole, single bearing, brushless, electronic
regulated. 10kW/12.5 kVA/3x380-415/220 240V@50Hz
Fuel:
Diesel fuel or kerosene based fuels as JP-5; JP-8,
NATO F34 and JET-A |
|
Fans: |
|
Evaporator:
1 propeller,
Æ356mm,
0.25 HP, 1500 rpm, 50 Hz
Condenser:
1 propeller,
Æ406mm,
1.33 HP, 3000 rpm, 50 Hz
Options:
Dual voltage, Remote monitoring,
Temperature recorder
Controls:
Microprocessor control with automatic
pre-trip and
diagnostics
Indicator lights: LEDs for operation and alarm
Automatic
phase sensing and correction
Safety shut down functions |
Controls:
Power circuit breaker
“On”–“Off” and “Start–Preheat” toggle switches
Voltmeter 0-600 VAC
DC Amp-meter
Hour-Meter
Oil pressure and Coolant temperature gauges
Automatic shut down for high coolant temperature and low oil
pressure
with light indicators
Battery Starting System:
Battery: 12V / 630 CCA @ -18°C
14V / 40A battery charging alternator
12V / 0.8 kW starting motor |
|
|
Features:
Compact design with removable Genset Reliable and simple to
use
Microprocessor control with automatic
pre-trip and
diagnostics
Easy access for service and maintenance
Alarm
system
Battery charger in operation when Genset
is stopped |
|
|
|
|
|
Return Air Temp. |
Net Capacity |
Power |
|
2°C
|
2,771
kCal/Hr |
4.5 kW |
|
-18°C
|
2,292 kCal/Hr |
4.1 kW |
|
|
|
|
|
|

|
|
|
All specifications are subject to
change without notice. For further information
about
this or any Klinge-product,
please
contact us at any of our
offices. |
|
|
|
|
|
|