Picture Frame Refrigeration Unit: MODEL PFR-571 ZII-II
Klinge's Explosion-Proof Refrigerated Container Model PFR-571 ZII-II was designed for operation in hazardous Zone 2 locations. The unit complies with the ATEX Directive 94/9/EC level of Ex II 3 G, Group IIA. Every component in the evaporator section is explosion proof, since this section is in direct contact with the cargo area. All external parts are also explosion-proof. The PFR-571 ZII-II was designed for 20' and 40' Insulated ISO Containers.
Defrosting of the evaporator coil is done with our unique and well proven “On Demand” hot-gas system, when required. The “On demand” defrost system assures that the optimal time for defrosting is chosen, which then assures that the maximum refrigeration time is obtained. In other words the defrost is not governed by a timer but by a sensor, sensing the heat transfer capabilities of the evaporator coil, so defrost is not started too early or too late.
The PFR-571 ZII-II is used to transport hazardous chemicals, resins, adhesives, pharmaceuticals, ammunition and other goods requiring extra protection. Klinge has been providing this model to major chemical and pharmaceutical companies around the world for nearly 30 years.
Klinge's machinery complies with International Customs Regulations for Containers, relevant ISO
recommendations, and the rules of B.V., ABS and Lloyds.
PFR-571 ZII-II PHOTOS

PFR-571 ZII-II FEATURES
» The
refrigeration unit design is compact, yet offers a large cargo area.
» Refrigeration system is just 14 in (365 mm) deep,
allowing for maximum cargo space.
» All components except
evaporator coil are easily serviced from the front of the unit.
» Easy access to all components in electric box. Door has lift off
hinges.
» Adjustable fresh air vent is labeled to indicate percentage of
opening.
» Bottom air discharge for better temperature distribution throughout
load.
» 50 Foot power cable with CEE 17 power plug is standard with cable
storage box.
» All electric, all-in-one cooling and heating unit.
» The unit is designed to fit into the front of a container and to serve
as the container front wall. Forklift pockets are provided for the
installation and removal of the unit.
PFR-571 ZII-II SPECIFICATION
» Dimensions: L
2025.5 mm (79.72 in), W 365 mm (14.4 in) from
back of flange,
H 2235.2 mm (80 in)
» Weight: 532 kg (1170 Lb)
» Ambient Temperature Range: -30°C (-22°F) to
52°C (125°F)
» Designed to Operate on both: 400/480 volt AC
±10%, 3 phase 50/60 Hz ±2.5%, and 230 volt AC ±10% 3 phase 60 Hz ±2.5%,
by use of a 230-480 volt step up transformer
mounted on the unit.
» Control Circuit: provided by a single-phase
transformer which steps down the high voltage power source to 24 volt AC
single phase
» Compressor: Hermetic Scroll, Displacement
498 CFH, Speed
3450 rpm, Protection
- Automatic reset, Valve
Suction and discharge with connection for gauge
Evaporator Coil: Copper Tube Material, Aluminum
Fin Material, Special Aluminum DIN 1712/A1 99, Fin Space 4.23mm (6 per
in), Attitude Slanted, Surface Area
465 ft2 (43.2m2), Protection - Surface treated with Hydrophilic surface
to resist corrosion induced by salt spray atmosphere. Pipe Copper
according to DIN 1787 wall thickness 0.45 mm
» Condenser Coil (air cooled): Copper
Tube Material, Aluminum Fin Material, Fin Space 3.07mm (10 per in),
Attitude Horizontal, Surface Area 293ft2 (25m2),
Protection - Treated with Epoxy paint to resist corrosion induced by
salt spray atmosphere, Pipe copper according to DIN 1787.
» Evaporator Fans (quantity 2):
Speed 1725 rpm, Aluminum Impeller Material with a high inherent
corrosion resistance, Drive Direct on motor shaft
» Evaporator Fan Motors (quantity 2):
Nominal HP 1/4, Explosion Proof Type,
Speed 1725 rpm, Bearing Ball Sealed, Stainless Steel Shaft Material,
Protection -
Internal thermal automatic reset, Class Zone 2, Groups IIA
» Condenser Fan (quantity 1): Propeller
type, Diameter 20 3/4 in, 14, Plastic Material (PPG), Drive Direct
on motor shaft, Air Flow 1800 CFM, Speed 1740 rpm
» Condenser Fan Motor: Nominal HP 1,
Explosion Proof Type, Speed 1740 rpm,
Bearing Ball Sealed, Stainless Steel Shaft Material, Protection -
Internal thermal automatic reset, Class Zone 2, Groups IIA
» Test method according to ARI standard no. 1110-69 approval
Net cooling capacity at 37.8°C (100°F)
ambient temperature at 60 Hz power.
| Return air temp to evaporator | Gross Comp Capacity | Fan Heat | Net Capacity | Power requirement |
|
35oF |
21450 BTU/Hr 6287W |
900 BTU/Hr |
20,550 Btu/HR |
6800W |
|
0oF |
12,020 BTU/Hr |
970 BTU/Hr |
11,050 Btu/Hr |
3800 W |
Net heating capacity (including Fan Heat) at 60 Hz power
System Heating Capacity 4343W (3714 Kcal/H)
» OPTIONS: Satellite communication system for remote and monitoring of the set temperature, supply temperature, return air temperature, alarm indication & power ‘on’ indication. Special dual voltage transformer enables refrigeration units to also operate on 220 volt 3 phase power. Other options include lighting, air curtains, temperature recorder, and shelving.