CONTAINERIZED SYSTEM
TCR-104 and NMG-112 |
|
|
|
 |
|
|
|
|
|
|
TCR-104 Refrigeration
Unit |
NMG-112 Generator Set |
|
|
|
|
General Information: |
General Information: |
|
The TCR-104 is an all aluminum refrigeration unit designed
to
provide high reliability in extreme ambient temperature. A
refrigeration system consists of its own compressor,
refrigerant piping, condenser coils, thermal expansion
valve, chiller, pump, expansion tank and a condenser fan and
motor. |
The NMG-112 Generator Set was designed for use in the
20’ x 8’ containers and the 20’ x 8’6” containers. The
design is compact yet offers easy access to all service
parts.
|
|
|
|
Construction:
Frame is constructed of aluminum
treated to resist corrosion induced
by salt spray atmosphere. |
Construction:
Aluminum frame
Aluminum doors and closures
Stainless Steel Hardware |
|
|
|
Temperature Range:
-40°C to +50°C |
Temperature Range:
-35°C to + 50°C |
|
|
|
Dimensions:
Width: 2140 mm (84.25 in)
Height: 685 mm (27 in)
Depth: 529 mm (20.83 in) |
Dimensions:
Length: 2102 mm
Depth: 521 mm
Height: 775 mm |
|
|
|
Weight:
331 kg (730 LB) |
Weight:
300 kg without fuel, 430 kg with fuel |
|
|
|
Compressor:
1 Copeland discus compressor
Condenser
Coil:
Copper tubes, aluminum fins - corrosion treated |
Engine:
Yanmar, three cylinder, 4 stroke, liquid cooled
16.1 kW @ 3600 rpm / 13.1 kW @ 3000
|
|
|
|
Refrigerant:
R-404a
Condenser Fan:
One propeller, 559 mm
(22 in) diameter, 2.0 HP |
Alternator:
Three phases; 2 pole; Single bearing; Brushless; Electronic
regulated; 10kW/12.5
kVA/3x380-415/220-240V@50Hz |
|
|
|
Controls:
Microprocessor with automatic pre-trip and diagnostics
Indicator lights: 8 LEDs for operation and alarm conditions
Voltage 460 V AC/6OHz and 380V AC/5OHz
Phase sensor for automatic phase correction
|
Fuel :
Diesel fuel or kerosene based fuels as JP-5;
JP-8,
NATO F34 and JET-A |
|
|
|
Options:
Heater 5 KW; Datalogger; Extra Probes; Dual voltage
transformer; Alarm lamp and horn; Satellite tracking and
monitoring |
Tank Capacity:
144 liter for approximately 50 hours of operation
|
|
|
|
|
Net
Cooling Capacity at 100°
F (37.7° C)
Ambient Temp. at 60 Hz Power
|
Leaving Glycol Temp. |
Net Capacity |
|
0°F / -17.7°C |
4190 Kcal/h / 16,700 BTU/Hr |
|
35°F / 0°C |
6518 Kcal/h / 26,000 BTU/Hr |
|
Controls:
Power circuit breaker
“On”–“Off” and “Start–Preheat” toggle switches
Voltmeter 0-600 VAC; DC Amp-meter
Hour-Meter
Oil pressure and Coolant temperature gauges
Automatic shut down for high coolant temperature
Low oil pressure with light indicators |
|
|
|
Download the Brochure:
4TCR-104
and NMG-112 System |
Battery Starting System:
Battery: 12V / 630 CCA @ -18°C
14V / 40A battery charging alternator
12V / 0.8 kW starting motor |
|
|
|
|
All specifications are subject to
change without notice. For further information
about this or any Klinge-product,
please
contact us at any of our
offices. |
|
|
|
|