TANK CONTAINER REFRIGERATION
Klinge's Tank Container Refrigeration Units (TCR) heat and cool the tanks cargo by circulating brine or synthetic oil around external cooling coils in the tank. This system is used to transport hazardous and non-hazardous chemicals, pharmaceuticals, food products and beverages.
All Tank Container Refrigeration units are designed to be fitted to ISO containers and tanks. Depending on the tank details and the options selected, the units have the stated cooling capacity at 0°C. All units have the option of heating between 5 to 20 kW. Klinge offers the following TCR models:
TCR-109: Tank
Container Refrigeration Unit


» All aluminum refrigeration unit designed
to provide high reliability in extreme ambient temperature.
» Electrical control panel and expansion tank are mounted
separately.
» Designed to work with the cooling coil system
provided by the tank builder. Klinge will give advice on routing
and venting pipes and heat calculations and may also provide the
air vents as part of the installation kit.
» Length: 1499 mm (59 in), Height - 571 mm
(22.47 in), Depth - 500 mm (19.68 in)
» Weight: 144 kg (317 lb)
» OPTIONS: datalogger, 5 kW heater, additional horn and strobe warning lights,
extra probes, satellite communication, dual voltage transformer, frame
or beam tank mounting, non pressurized expansion tank, dual system for very hazardous cargo,
alternative heat transfer fluids for high and extreme low temperatures
» Net cooling capacity at 37.8°C (100°F)
ambient temperature at 60 Hz power.
Return air temperature:
Net Capacity:
-17.8°C / 0°F
2270 Kcal/h / 9000 BTU/hr
1.7°C / 35°F
3400 Kcal/h / 13,500 BTU/hr
TCR-104: Tank Container Refrigeration Unit
» All aluminum refrigeration unit designed
to provide high reliability in extreme ambient temperature.
» Available with generator set.
» The connection to the tanks coil system is
made, with the necessary components, built into the tank and supplied by
the tank builder.
» Width - 2140 mm (84.25 in),
Height - 685 mm (27 in),
Depth - 529 mm (20.83 in)
» Weight: 331 kg (730 lb)
OPTIONS: datalogger, 5 KW heater, alarm lamp and horn, extra probes,
satellite communication, dual voltage transformer
» Net cooling capacity at 37.7°C (100°F)
ambient temperature at 60 Hz power.
Leaving glycol temperature:
Net Capacity:
0°F / -17.7°C
4190 Kcal/h / 16,700 BTU/Hr
35°F / 0°C
6518 Kcal/h / 26,000 BTU/Hr
TCR-262: Tank Container Refrigeration Unit
The
TCR-262 is a dual system with two refrigeration systems which provide
100% security for hazardous cargoes. The unit has two independent
microprocessor thermostats that control and monitor the cargo
temperature. These thermostats raise visual, audible and remote alarms
if the required cargo parameters are not being met. The unit is “nose
mounted” in the front of the container and can be made totally
independent by connecting it to the associated generator
NMG-112.
» Dimensions: L 83 in
(2108 mm), H 47.75 in (1213 mm), D 21.5 in (546 mm) from back of
flange - 25.5 in (650 mm) overall
» Weight: 1341 lbs (608 kg)
»
OPTIONS: Hour meter, 3 Phase Dual Voltage Transformer, 460 V Receptacle on Transformer Cable, 230 Volt Plug on Transformer Cable, Converter Adapter 250V AC 50 Amp plug to 60 Amp Receptacle, Dummy receptacle and stainless steel cable retainer, Suction and Discharge Gauge,
datalogger,
satellite communication
» Capacity: 100ºF / 37.8ºC Ambient Temperature at 60 Hz power.
Supply Glycol Temperature
Net Capacity
Power Requirement
35°F / 1.7°C
7800 Kcal/h 9144 W 10.75 KW
0°F / -17.8°C
6075 Kcal/h 7121 W 9.4 KW
TANK CONTAINER HEATING
Klinge's Tank Container Heating System is an all aluminum and steel fabrication consisting of an electrical resistance heater, pump and control box. The heater provides electrical heating by pumping a heat transfer fluid around existing steam coils or wrap around plates on the tank. Read more.
TCH-106: Tank
Container Heater


» All aluminum and steel fabrication consisting of an electrical
resistance heater,
pump and control box
» TCH-106 is the base, 6 kW, unit with a thermostat built into the
heater element controlling the glycol temperature. It requires no
additional control box. All other units have a sensor in the cargo and
an enclosure housing the controls.
» Weight 36 kg (80 lb) for the pump assembly, 30 kg (68 lbs) for the
control box and power cable
» Gross heating capacity of the standard model at 37.8°C (100°F)
ambient temperature at 60 Hz power is considered as 6kw. The net heating
capacity will depend on the tank details and interconnecting pipe
details and their insulation.
» OPTIONS: Electrical control boxes (large square, beveled to fit dished
end, baby box), additional options for the large square and beveled to
fit dished end options include additional thermocouples, frame
temperature limit for ultra high temperatures, visual and audible
alarms, large explosion proof strobes lamps mounted at the top of the
tank rear frame, no power alarms, datalogger,
satellite communication